Our IP67 rated BLident interface modules are available with up to 16 channels and with PROFIBUS-DP, PROFINET I/O, DeviceNet™, CANopen, Ethernet/IP and Modbus TCP communication.
We also offer programmable gateways with Modbus/TCP and Ethernet/IP communication for distributed and fast signal processing.
Thanks to the modular concept, you can plug input and output modules to the interface at a later stage.
All channels operate parallelly allowing simultaneous transmission of data.
Fieldbus diagnostics, supply voltage and the status of the individual channels are indicated via LEDs and complemented by fieldbus-specific diagnostic messages.
We offer standard function modules for easy integration in the control and fieldbus network.

 Power search
 Info material
 BL67 - modular I/O system in IP67
 Show products (21)

Info material Description File size Download
Product catalogue BL67 - modular fieldbus I/O system in IP 67
5311 KB  
Product flyer fieldbus system BL67
2110 KB  
Product flyer BLident UHF
1581 KB  
Product flyer RFID system for the explosion hazardous area
718 KB  
Product flyer RFID solutions for chocolate production
651 KB  
BL20/BL67 supplementary manual for PROFIBUS-DPV1
869 KB  
User manual User manual BL ident, commissioning with the Proxy-Ident function block for PROFIBUS-DP
3449 KB  
User manual Commissioning with the Proxy-Ident function block for CoDeSys
5683 KB  
User manual BL67 prog. EtherNet/IP Gateway - BL67-PG-EN-IP
3469 KB  
User manual 6 User manual for BL67-PG-EN
5624 KB  
User manual 7 User manual RFID, Commissioning with the Proxy-Ident function block for ProfiNet
1669 KB  


Products:
 
 
Short description Dimension drawing Description
Extension module BL ident for use with function module or with programmable Gateway
Interface for connection of BL ident read/write heads (HF/UHF)
Type: BL67-2RFID-A
Ident-Nr.: 6827225
  • This module is used in conjunction with the
    BL67-GW-DPV1
  • Protection class IP67
  • LEDs indicating status and diagnostics
  • Electronics galvanically isolated from the field level via opto couplers
  • connection of 2 BLident ® write-read heads
  • Mixed operation of HF and UHF read/write heads
  • Transmission rate: 115.2 kbps
  • Cable length: 50 m max.
Set for Profibus DPV1 in IP67
Type: TI-BL67-DPV1-2
Ident-Nr.: 1545028
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches for the adjustment of the Profibus address
  • Maximum transmission rate to the fieldbus 12 Mbps
  • Two 5-pole reverse-keyed M12 x 1 connectors for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 2 read/write heads (HF/UHF) via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for Profibus DPV1 in IP67
Type: TI-BL67-DPV1-4
Ident-Nr.: 1545029
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches for the adjustment of the Profibus address
  • Maximum transmission rate to the fieldbus 12 Mbps
  • Two 5-pole reverse-keyed M12 x 1 connectors for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 4 read/write heads (HF/UHF) via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for Profibus DPV1 in IP67
Type: TI-BL67-DPV1-6
Ident-Nr.: 1545030
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches for the adjustment of the Profibus address
  • Maximum transmission rate to the fieldbus 12 Mbps
  • Two 5-pole reverse-keyed M12 x 1 connectors for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 6 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for Profibus DPV1 in IP67
Type: TI-BL67-DPV1-8
Ident-Nr.: 1545031
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches for the adjustment of the Profibus address
  • Maximum transmission rate to the fieldbus 12 Mbps
  • Two 5-pole reverse-keyed M12 x 1 connectors for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 8 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for PROFINET IO in IP67
Type: TI-BL67-EN-PN-2
Ident-Nr.: 1545040
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches to adjust the bus address
  • Maximum transmission rate to the fieldbus 10/100 Mbps
  • One 4-pole M12 connector, D-coded, for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 2 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for PROFINET IO in IP67
Type: TI-BL67-EN-PN-4
Ident-Nr.: 1545041
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches to adjust the bus address
  • Maximum transmission rate to the fieldbus 10/100 Mbps
  • One 4-pole M12 connector, D-coded, for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 4 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for PROFINET IO in IP67
Type: TI-BL67-EN-PN-6
Ident-Nr.: 1545042
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches to adjust the bus address
  • Maximum transmission rate to the fieldbus 10/100 Mbps
  • One 4-pole M12 connector, D-coded, for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 6 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Set for PROFINET IO in IP67
Type: TI-BL67-EN-PN-8
Ident-Nr.: 1545043
  • Up to 50m cable length between interface and read-write head
  • 3 decimal coded rotary switches to adjust the bus address
  • Maximum transmission rate to the fieldbus 10/100 Mbps
  • One 4-pole M12 connector, D-coded, for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 8 read/write heads via BLident ® M12 connecting cables
  • Mixed operation of HF and UHF read/write heads
Programmable set for PROFIBUS-DP in IP67
Type: TI-BL67-PG-DP-2
Ident-Nr.: 1545061
  • Programmable acc.to IEC 61131-3 with CoDeSys
  • Up to 50m cable length between interface and read-write head
  • 12 Mbps
  • 5-pole reverse-keyed M12 connector for fieldbus connection
  • One 5-pole 7/8" connector for power supply
  • LEDs for display of supply voltage, group and bus errors as well as status and diagnostics.
  • Connection of up to 2 read/write heads via BLident ® M12 connecting cables